The Watertech Controlpres is an automatic controller which allows the setting of the working pressure. The Controller will start and stop the pump depending on opening and closing of the taps and offers run dry protection. It comes equipped with automatic restart in case of failure and anti-jamming function. Ideal for above ground pumps and submersible pumps up to 3 HP. The working pressure and start pressure are adjusted by turning the knob on the back of the device.
Features
Adjustable start and output pressure
Run Dry Protection
Power: 1.1kW (1.5 HP) -115V – 2.2kW (3 HP) – 230V
A user-friendly interface with LED indicators displaying power status, pump running and alarm indication.
Wetted parts are made from high quality corrosion resistant materials
1 1/4 male connections to guarantee a higher flow rate
Pressure Gauge
No need for an expansion tank, check valve, filter or fittings.
Technical Features
Pressure regulating range: 3 – 6.5 bar
Max Current: 16A
Max Operating Pressure: 12 Bar
Single Phase-115/230
Frequency: 50-60 Hz
Protection Grade: IP65
Max Temperature: 65°C
Minimum Flow Rate-1 LPM
IP65
Certifications: TÜV SÜD
Installation and Startup
The device can be installed directly on the pump or between the pump and the first tap.
Make all the electrical connections, check that the pump is correctly primed, open a tap and energize.
The green Power on led will light up on the control panel and the pump will start (yellow “Pump on” led on) and will keep running for several seconds to pressurize the system. If this time is insufficient, the device will stop the pump (red “Failure” led blinking). Press and hold down the Restart button until the red Failure led turns off and the water comes out of the open tap. When the tap is closed, the pump will stop after a few seconds (yellow “Pump on” led turns off).
From now on, the device will turn the pump on and off depending on the opening and closing of the tap.
To set the required pressure turn the knob on the back of the device (regulation range from 3 to 6,5 bar).
In case of water shortage, the device will stop the pump and protect it from dry running (red “Failure” led blinking).
In case of a temporary blackout, the device will automatically rearm once the electricity returns.
Automatic Restart and Anti-Jamming Function
In case of stopping due to a water shortage, the device will automatically make 10 double attempts to rearm over the 24 hours following the failure, each lasting approximately 5 seconds to allow the pump and the system to reload if possible.
The user can try to rearm the device at any time by pressing the Restart button.
If for any reason the pump remains idle for 24 consecutive hours, the device will carry out a start-up of the pump motor for about 5 seconds.
Model Controlpres
Start Pressure 1.2–4.5 Bar
Output Pressure 3–6.5 Bar
Inlet/Outlet 32mm
Phase 1
Voltage 220-240
Frequency 50–60 Hz
Max Power 2.2kW