Bedford B603B-4010: B603B-4010

$1,138.50

SKU: B603B-4010 Category:

The Bedford 600 series is a variable speed drive to enhance the performance of single phase and three phase water pumps up to 7.5 kW. The 600 series eliminates the requirement for large pressure tanks and pressure switches used for automatic operation as well as associated pressure cycling.

The Bedford 600 series provides both the ability to conserve energy through only operating the pump according to the speed required to maintain constant pressure and further allowing for multiple set points to be met.

The Bedford 600 series is equipped with an easy to use LCD display and is completely designed and built for controlling pump systems from the ground up.

Features

IP55
Mounting bracket included
A Pressure Transducer 4-20mA, 1mPa is required for operation (sold separately)
Constant water pressure.
Optimises pump performance.
Soft start, low motor start current.
No large pressure tank required.
Dry run protection.
High and low voltage protection.
Input and output short circuit protection.
High and low water pressure protection.
Input and output phase failure protection.
Over temperature protection.
Sensor fault protection.

Technical Features – Input & Output

Input Voltage Range 240±15% and 415±15%
Input Frequency Range 47~63Hz
Output Voltage Range 0~rated input voltage
Output Frequency Range 0~50/60Hz
Digital Switch Input 3 input
Analogue Signal Input – AI1:0~10V or 0~20mA input; AI2: 0~10V or 0~20mA Input
Relay Output A pair of switched Outputs

Function Characteristics

According to the water condition to supply constant pressure water without manual operation after parameters are set correctly.
Stop running automatically when there is no water consumption and Alarm automatically when faults occur
Adapts to many kinds of inputs.* Sleep Function – Sleep down when there is no water consumption for energy saving
Freeze-Proofing Function – Suitable for low temperature area, prevent pump from freezing
Anti-clogging Function – take precaution against pipe clogging
Power On Restart – Setting to allow automatic pump start when powered on
Day-Part Function – 3 independent day-part control, up to 7 day-part achieved when defined
Terminal Control Mode – Terminal Run/Stop, Manual/Auto Control, Electronic Contact Gauge Control
Various water supply Fault Alarm Functions: High-Pressure, Low-Pressure, Low-Level, Transducer Error etc.
As many as 22 kinds of fault protection function: Over-Current, Over-Voltage, Low-Voltage, Over-Load etc.
Professional design based on users’ needs, simplicity of operation and suitable for all kinds of applications.

Model

Max hp

Max kW

Phase (Input)

Phase (Output)

Voltage

B601B-2002

2.0

1.5

Single

Single

220-240

B603B-2002

2.0

1.5

Single

Three

220-240

B603B-2003

3.0

2.2

Single

Three

220-240

B603B-4003

3.0

2.2

Three

Three

415

B603B-4010

10

7.5

Three

Three

415